JAEA Reports

Sodium combustion analysis for the secondary heat transport system of prototype fast breeder reactor MONJU

; Ohno, Shuji;

JNC TN2400 2000-006, 56 Pages, 2000/12

JNC-TN2400-2000-006.pdf:1.22MB

Sodium combustion analyses were performed using ASSCOPS version 2.1 in order to obtain background data for evaluating the validity of the mitigation system against secondary sodium leak of MONJU. The calculated results are summarized as follows. (1)Peak atmospheric pressure $$sim$$ 4.3 kPa[gage] (2)Peak floor liner temperature $$sim$$ 870$$^{circ}$$C, Maximum thinning of liner $$sim$$2.6mm (3)Peak hydrogen concentration <2% (4)Peak floor liner temperature in the spilt sodium storage eell $$sim$$ 400$$^{circ}$$C , Peak floor concrete temperature in the spilt sodium storage cell $$sim$$ 140$$^{circ}$$C.

JAEA Reports

Mechanical integrity of floor liner in secondary heat transport system cells of Monju

; ; Ueno, Fumiyoshi; ; ; ;

JNC TN2400 2000-005, 103 Pages, 2000/12

JNC-TN2400-2000-005.pdf:3.98MB

Inelastic analyses of the floor liner subjected to thermal loading due to sodium leakage and combustion were carried out, considering thinning of the liner plate due to molten salt type corrosion. Because the inelastic strain obtained by the analyses stayed below the ductility limit of the material, mechanical integrity, i.e., there exist no through-wall crack on the floor liner, was confirmed. Partial structural model tests were conducted, with a band of local thinning of the liner plate. Displacements were controlled to give specimens much larger strains than those obtained by the inelastic analyses above. No through-wall crack was observed by these tests. Mechanical integrity of the floor liner was confirmed by these results of the inelastic analyses and the partial structural model tests.

JAEA Reports

Sodium pooI combustion Test (Run-F7-3 and Run-F8-1) to confirm the condition of floor liner's corrosion

; ; Ohno, Shuji;

JNC TN9400 2000-092, 247 Pages, 2000/08

JNC-TN9400-2000-092.pdf:20.29MB

Small-scale sodium pool combustion tests Run-F7-3 and Run-F8-1 were performed to investigate the corrosion of floor liner under high moisture condition. ln the both tests, which were performed using the 3m$$^{3}$$ FRAT-1 vessel at the SAPFIRE facility, the sodium of 507deg-C was leaked on the carbon steel catch pan about for 25 minutes with the flow rate of around 25 kg/h. The air in the vessel was ventilated with the flow rate of 5m$$^{3}$$/min containing the moisture of 25000-28000 vol.ppm. The duration of combustion was different in two tests by changing the starting time of argon gas injection into the vessel. As the results of post-test analysis such as observation of catch pan surface and chemical analysis of the deposits, it was confirmed that 'Na-Fe double oxidization type corrosion' was dominant in the both tests and that the catch pan and deposits were not under the condition leading to the occurrence of 'molten salt type corrosion.'

JAEA Reports

Corrosion bihavior of carbon steel in high-temperature sodium compounds; Recommended equation for corrosion rate of the carbon steel in sodium compounds (Na$$_{2}$$O$$_{2}$$-NaOH System)

Yoshida, Eiichi; Aoto, Kazumi; Hirakawa, Yasushi;

JNC TN9400 2000-024, 42 Pages, 1999/10

JNC-TN9400-2000-024.pdf:1.63MB

For the purpose of improving the reliability of evaluation, the corrosion rate equation of the carbon steel SM400B (JIS G3106) in the high-temperature sodium compounds (NaOH-Na$$_{2}$$0$$_{2}$$ system) was revised. ln this revision, the data acquired after 1997 was used. Based on the experimental results, the evaluation was made to be an approach to the following; (1)Metal loss of carbon steel in NaOH-Na$$_{2}$$0$$_{2}$$ system was evaluated as increases in exposure to the time, which is linear rate law. (2)There were no significant effects of the experiment atmosphere and mixing speed of the reagent on corrosion rate. (3)The concentration of Na$$_{2}$$0$$_{2}$$ in sodium compound is considered for the evaluation. The concentration under experiment is made to be the over concentration necessary for maintaining the dominant reaction between Fe and Na$$_{2}$$20$$_{2}$$. As a result of the evaluation, the additional data are 67 points. The data for the revision of the evaluation equation became the total of 105 points, when existing data of 38 points were added. The statistical evaluation of 105 points was carried out, and following recommended equation was obtained. C$$_{R}$$ = C exp(-Q/RT) Where; C$$_{R}$$ : Corrosion rate, mm/h C : Material constant Q : Apparent activation energy, cal/mol R : Gas constant, 1.986 cal/mol K T ; Absolute temperature, K Q = 9.61 kcal/mol C = 148.29 (average), 262.11 (99% UCL), 83.90 (99% LCL)